DATAKOM: ATS, AMF, AVR, ECM, DKG controllers for diesel, gas, petrol gensets including manual start and auto mains failure generator controls, electronic engine governors, alternator automatic voltage regulators, automatic transfer switches, battery chargers, meters and analyzers, contactors, synchroscopes and automatic synchronizers for multi generating set paralleling and mains synchronization. Buy Datacom online.

DATAKOM DFC-0124 Power Factor Controller, 128x64 B&W display,144x144mm, 24steps + RS485 + SVC

Datakom DATAKOM DFC-0124 Power Factor Controller, 128x64 B&W display,144x144mm, 24steps + RS485 + SVC
Datakom DATAKOM DFC-0124 Power Factor Controller, 128x64 B&W display,144x144mm, 24steps + RS485 + SVC
Datakom DATAKOM DFC-0124 Power Factor Controller, 128x64 B&W display,144x144mm, 24steps + RS485 + SVC
(0)
$433.00
pcs.

DATAKOM DFC-0124 SVC ENABLED REACTIVE POWER CONTROLLER

The DFC-0124 is an advanced, precision 24 step power factor control and metering device offering unrivalled internet monitoring capabilities in a standard 144x144mm panel mount enclosure.
The unit has various models offering 12-18-24 step outputs. Outputs can be selected as contactor or static switch drivers in blocks of 6. Every output is capable of driving single or three phase, capacitor or reactor.
The unit is very simple to install and commission thanks to the automatic setup and connection correction features.
Vast communication capabilities are embedded to the unit. It does not require any external component.
The unit itself is a web page and can be opened through any browser for remote monitoring. The central monitoring feature can monitor thousands of meters on one screen.
Thanks to its SVC outputs it can match the exact target pf value independently of capacitor rating selections.

SVC SYSTEM:
SVC stands for “Static Var Compensation”.
The unit has 3 SVC outputs which are duty cycle controlled PWMs that control 3 reactors with a precision of 1000 steps.
Thus the controller is able to supply almost any required reactive power on each phase, enabling matching the exact required PF, independently from capacitor bank selection.

FEATURES:
• Easy to use with user friendly menu system
• Easy automatic setup under load
• Automatic correction of connection faults
• Measurement period: 10-100ms adjustable
• Reactive correction in 20ms
• 24-18-12 step output options
• All steps can drive capacitors/thyristors
• All steps can be mono or tri-phased
• Always exact correction with SVC outputs
• 0.5% measurement accuracy, true RMS
• 32 bit power measurement accuracy
• Low current compensation capable (3mA)
• Graphic LCD display, 128x64 pixels
• Harmonic measurements of all voltages and currents
• Harmonic distortion display (31 harmonics)
• Oscilloscope, waveform display
• Ready for remote monitoring over GPRS and LAN
• Geo-location over GSM
• Remote parameter adjustment
• Remote step control enabled
• Long term data recording on USB flash memory
• Battery backed-up real time clock
• 250 event records with date-time
• User configurable display screens
• Adjustable alarm limits
• Configurable relay outputs
• Voltage transformer ratio for MV applications
• Password protected front panel programming
• Reduced panel depth
• Sealed front panel (IP65 with gasket)

COMMUNICATIONS:
• GSM-SMS sending
• e-mail sending
• Central Monitoring through IP
• Web monitoring
• Web programming
• Free configuration & monitoring software
• Modbus RTU RS-485
• Modbus TCP/IP
• SNMP
• TCP/IP server
• TCP/IP client
• UDP
• SMTP

TECHNICAL SPECIFICATIONS
Power Supply Input:
85 to 270V AC
50 - 60Hz nominal (± 10%)
Power Consumption: < 15 VA
Measurement Input Range:
Voltage: 5 - 300 V AC (L-N)
10 - 520 V AC (L-L)
Current: 0.005 - 5.5 A AC
Frequency: 30 - 100 Hz
Accuracy:
Voltage: 0.5%+1digit
Current: 0.5%+1 digit
Frequency: 0.2%+1 digit
Power(kW,kVAr): 1.0%+2digit
Power factor: 0.5%+1digit
Measurement Range:
CT range: 5/5A to 10’000/5A
VT range: 0.1/1 to 5000.0/1
kW range: 0.1 kW to 6.5MW
Voltage burden: < 0.1VA per phase
Current burden: < 0.5VA per phase
Number of step outputs: 24
Relay Outputs: 5A @ 250V AC
Static Contactor Outputs: 50mA @ 12V DC
SVC Outputs: 50mA @ 12V DC
Temperature Input: PT100 sensor or switch (optional)
Operating Temperature:
-20°C to +70°C (-4 to +176 °F).
Maximum humidity: 95% non-condensing.
Degree of Protection: IP 65 (Front with gasket)
IP 30 (Back)
Enclosure: Non-flammable, ROHS compliant
Installation: Flush mounting with rear brackets
Dimensions: 164x164x69mm (WxHxD)
Panel Cutout: 140x140mm
Weight: 700 gr
EU Directives:
2006/95/EC (LVD)
2004/108/EC (EMC)
Norms of reference:
EN 61010 (safety)
EN 61326 (EMC)


WE DO NOT SHIP THIS DATAKOM PRODUCT TO USA AND CANADA



  • Previous Generation Products
  • 4PRO Contactors and Load Transfer Switches
  • 4PRO Wireless remote control sets
  • Software and Access Licenses
DATAKOM: ATS, AMF, AVR, ECM, DKG controllers for diesel, gas, petrol gensets including manual start and auto mains failure generator controls, electronic engine governors, alternator automatic voltage regulators, automatic transfer switches, battery chargers, meters and analyzers, contactors, synchroscopes and automatic synchronizers for multi generating set paralleling and mains synchronization. Buy Datacom online.