DATAKOM: ATS, AMF, AVR, ECM, DKG controllers for diesel, gas, petrol gensets including manual start and auto mains failure generator controls, electronic engine governors, alternator automatic voltage regulators, automatic transfer switches, battery chargers, meters and analyzers, contactors, synchroscopes and automatic synchronizers for multi generating set paralleling and mains synchronization. Buy Datacom online.

DATAKOM DKG-329 Generator/Mains Automatic transfer switch control panel (ATS) with synch check

Datakom DATAKOM DKG-329 Generator/Mains Automatic transfer switch control panel (ATS) with synch check
Datakom DATAKOM DKG-329 Generator/Mains Automatic transfer switch control panel (ATS) with synch check
(0)
$270.00
pcs.

The DATAKOM DKG-329 is a control and protection panel designed to monitor 3-phase mains voltages, send remote start command to generating sets and make changeover of both generator and mains contactors.
The unit offers an internal synchroscope for uninterrupted transfer in both directions. The number of gensets to run before transfer is selectable, allowing multiple genset support.
In AUTOMATIC position, the unit monitors mains phase voltages. In case of a mains failure it controls the remote starting and load transfer of the generating set, and once the generator is running, it monitors internal protections and external fault inputs. If a fault condition occurs, the unit disables the remote starting automatically and indicates the failure source with the corresponding led lamp and text.
The unit provides a comprehensive set of digitally adjustable program parameters. All programs may be modified via front panel pushbuttons and do not require any external unit.
The unit is able to initiate modem calls and sending SMS messages in fault conditions.
It is possible to monitor and control the operation of the system locally or remotely with the WINDOWS based RAINBOW program.
The unit supports MODBUS protocol enabling communication with PLCs and building management systems. The MODBUS protocol is also supported through GSM and PSTN modems.

MEASUREMENTS

Generator Volts: L1-N, L2-N, L3-N
Generator Volts: L1-L2, L2-L3, L3-L1
Generator Frequency
Mains Volts: L1-N, L2-N, L3-N
Mains Volts: L1-L2, L2-L3, L3-L1
Mains Frequency
Load Amps: L1, L2, L3
Load kW: L1, L2, L3, total
Load kVAr: L1, L2, L3
Load pf: L1, L2, L3, total
Synchroscope Phase Angle
Battery Voltage

FEATURES

True RMS measurements
Synchroscope & check synch
No break transfer& no break load test
Automatic contactor control
Multiple genset system support
Load shedding, dummy load
Event logging with time stamp and measurements
Battery backed-up real time clock
Built in daily / weekly / monthly exerciser
Weekly operation schedule programs
Field adjustable parameters
RS-232 serial port
Free MS-Windows Remote monitoring SW
GSM and PSTN modem support
GSM SMS message sending on fault
MODBUS communications
Multiple language support
Customer logo display capability
16 Amp contactor outputs
1 Amp DC semiconductor control outputs
Configurable digital inputs: 7
Configurable digital outputs: 3
Total digital outputs: 6
I/O expansion capability
Plug-in connection system
Sealed front panel

TECHNICAL SPECIFICATIONS

Alternator voltage: 0 to 300 V-AC (Ph-N)
Alternator frequency: 0-100 Hz.
Mains voltage: 0 to 300 V-AC (Ph-N)
Mains frequency: 0-100 Hz.
DC Supply Range: 9.0 to 33.0 V-DC
Cranking dropouts: survives 0 V for 100ms.
Typical Standby Current: 100 mA-DC
Maximum Operating Current: 200 mA-DC (Relay outputs open)
Generator/Mains Contactor Relay Outputs: 16 A / 250V
DC Outputs: 1A @ 28V protected semiconductor output
Current inputs: from CTs, .../5A. Max load 0.7VA per phase.
Serial port: RS-232, 9600 bauds, no parity, 1 bit stop
Operating temp.: -20°C (-4°F) to 70 °C (158°F).
Storage temp.: -40°C (-40°F) to 80 °C (176°F).
Maximum humidity: 95% non-condensing.
Dimensions: 172 x 134 x 46 mm (WxHxD)
Panel Cut-out Dimensions: 151x111 mm minimum.
Weight: 300 g (approx.)
Case Material: High Temperature ABS/PC (UL94-V0)
IP Protection: IP65 from front panel, IP30 from the rear
Installation: Flat surface mounting on a Type 1 enclosure.
CE Conformity reference standards:
EN 61010 (safety requirements)
EN 61326 (EMC requirements)
UL / CSA Conformity: certificate # 20110527-E314374
UL 508, Edition 17
UL 2200, 1st Edition.
UL 840 Edition 3
CSA C22.2 NO. 14 - Edition 10

WE DO NOT SHIP THIS PRODUCT TO USA AND CANADA



DATAKOM: ATS, AMF, AVR, ECM, DKG controllers for diesel, gas, petrol gensets including manual start and auto mains failure generator controls, electronic engine governors, alternator automatic voltage regulators, automatic transfer switches, battery chargers, meters and analyzers, contactors, synchroscopes and automatic synchronizers for multi generating set paralleling and mains synchronization. Buy Datacom online.